[PCSF_46007] No gateway connectivity is provided for domain. ERROR: Cannot connect to Integration Service.

пятница, 1 ноября 2013 г. Оставить комментарий

Error: [PCSF_46007] No gateway connectivity is provided for domain [Domain_vminf]. ERROR: Cannot connect to Integration Service [is_vminf].


C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>pmcmd startworkflow -sv is_vminf -d Domain_vminf -u Administrator -p Administrator -f TEST -rin wf_test_0001 wf_test

Informatica(r) PMCMD, version [9.5.1 HotFix3], build [261.0906], Windows 32-bit
Copyright (c) Informatica Corporation 1994 - 2013
All Rights Reserved.

Invoked at Fri Nov 01 15:39:04 2013

[PCSF_46007] No gateway connectivity is provided for domain [Domain_vminf].
ERROR: Cannot connect to Integration Service [is_vminf].

Completed at Fri Nov 01 15:39:05 2013

C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>

Check the connection:


C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>pmcmd pingservice -sv is_vminf -d Domain_vminf

Informatica(r) PMCMD, version [9.5.1 HotFix3], build [261.0906], Windows 32-bit
Copyright (c) Informatica Corporation 1994 - 2013
All Rights Reserved.

Invoked at Fri Nov 01 15:48:52 2013

[PCSF_46007] No gateway connectivity is provided for domain [Domain_vminf].
ERROR: Cannot connect to Integration Service [is_vminf].

Completed at Fri Nov 01 15:48:53 2013

C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>

Cause: The pmcmd command is not able to find the domains.infa file to read the information.


Action: Set the environment variable INFA_DOMAINS_FILE.


C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>set INFA_DOMAINS_FILE=C:\Informatica\9.5.1\clients\PowerCenterClient\domains.infa


C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>pmcmd startworkflow -sv is_vminf -d Domain_vminf -u Administrator -p Administrator -f TEST -rin wf_test_0001 wf_test

Informatica(r) PMCMD, version [9.5.1 HotFix3], build [261.0906], Windows 32-bit
Copyright (c) Informatica Corporation 1994 - 2013
All Rights Reserved.

Invoked at Fri Nov 01 15:54:36 2013

Connected to Integration Service: [is_vminf].
Starting workflow [wf_test]
INFO: Starting execution of workflow [wf_test] in folder [TEST] last saved by user [Administrator].
Workflow wf_test with run instance name [WF_TEST_0001] and run id [42] started successfully.
Disconnecting from Integration Service

Completed at Fri Nov 01 15:54:38 2013

C:\Informatica\9.5.1\clients\PowerCenterClient\CommandLineUtilities\PC\server\bin>